| Preparation |
BARE
ALUMINUM: Sand with medium grade (grit) emery cloth to a bright
metal finish. Immediately apply Viny-Lux Primewash 353/354 thinned 25%
with Viny-Lux Solvent 355. Allow to dry for 1-24 hours. Apply 1 full can
of Primocon Aerosol Primer YPA985 in a multi-layer procedure.
PREVIOUSLY PAINTED SURFACES:
with Trilux Prop & Drive Aerosol: Sand with 80 grade (grit)
paper.
with Factory Finish or Antifouling Paint: Sand with 80 grade
(grit) paper. Clean with Special Thinner 216. Resand any areas where
bare aluminium is exposed with medium grade (grit) emery cloth and wipe
clean. Apply 1 full can of Primocon Aerosol Primer YPA985 in a
multi-layer procedure. |
|
|
| Method |
At
least 2 coats should be applied. Hold can 12-16 inches from the unit
when applying the paint. Wait for minimum overcoating time between
coats. Continue until the entire can has been used per outdrive. Be sure
the paint is completely dry before immersion and allow minimum immersion
time. |
|
|
| Hints |
Mixing Shake
can well, listening for mixing ball. Continue shaking for at least 1
minute.
Thinner Bare Wood - Special Thinner 216.
Thinning Spray - Special Thinner 216.
Cleaner Special Thinner 216.
Airless Spray Pressure: 170-204 bar/2500-3000 psi. Tip Size:
0.53 mm/21 thou.
Conventional Spray Pressure Pot: Pressure: 3.44-4.47
bar/50-65 psi (gun pressure); 10-15 psi (pot pressure). Tip Size:
1.8-2.2 mm/70-85 thou.
Other Put extra coats of Trilux Prop & Drive Aerosol on
the props and other running gear. For best antifouling protection use
entire can of primer and Trilux Prop & Drive Aerosol for each lower
unit. |
|
|
| Some
Important Points |
Product
temperature should be minimum 10°C/50°F and maximum 29°C/85°F.
Ambient temperature should be minimum 10°C/50°F and maximum 35°C/95°F.
Substrate temperature should be minimum 10°C/50°F and maximum 29°C/85°F. |
|
|
| Compatibility/Substrates |
Apply
to clean, dry, properly prepared surfaces only. Do not apply to
tin-based paint such as Micron® 33, 44 or Tri-Lux® IIT. Must be sealed
with Primocon Aerosol YPA985. |
|
|
| Number
of Coats |
2 |
|
|
| Coverage |
(Theoretical)
- 122.1 (ft²/Gal) 1 aerosol can will cover 1 lower unit (2 coats) |
|
|
| Recommended
DFT |
2.0
mils dry
|
| Application
Methods |
Aerosol