|

|

Interprotect 2000/2001
Interprotect® 2000E is the
newest development of Interprotect® 2000. It has many of the same
outstanding properties but does not contain methylene chloride. For this
reason it is designated with the “E’’ to be a more environmentally
preferred product.
Technically, the Interprotect®
Micro-Plate® formula provides millions of overlapping microscopic plates.
When bound in the epoxy coatings, they create an overlapping barrier
similar to shingles on a roof. Micro-Plates therefore eliminate any direct
path for water migration.
|
|
Part No. |
Description
(Click to view & order) |
Price |
Interprotect
2000E is a unique two part epoxy coating developed to protect new and
used fiberglass hulls from absorption which can lead to poor hull
performance and osmotic blistering.
* Contains Micro-plates® for extra protection
* Anticorrosive substrate primer for metals
Interprotect 2000E is used as part of the Interprotect system to repair
gelcoat blistering. Microplates® in Interprotect 2000E create an
overlapping barrier to eliminate any direct path for water migration. |
|
| Colour |
Y2000E-Gray,
Y2002E-White |
| Finish |
Matte |
| Specific
Gravity |
1.4 |
| Volume
Solids |
45% |
| Mix
Ratio |
3:1
by volume (as supplied) , Converter/Curing Agent - Y2001E |
| Typical
Shelf Life |
2
yrs |
| VOC
(As Supplied) |
464
g/lt |
| Unit
Size |
1
US Quart , 1 US Gallon |
|
| DRYING/OVERCOATING
INFORMATION |
| Touch
Dry [ISO] |
3hrs |
2hrs |
30mins |
|
| Immersion |
24hrs |
12hrs |
8hrs |
|
| Pot
Life |
7.5hrs |
3hrs |
2hrs |
|
|
|
Overcoating |
|
Substrate
Temperature |
|
50ºF |
73ºF |
95ºF |
|
| Overcoated
By |
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
|
|
| Bottomkote |
7hrs |
9hrs |
5hrs |
7hrs |
3hrs |
5hrs |
|
|
| Bottomkote
XXX |
7hrs |
9hrs |
5hrs |
7hrs |
3hrs |
5hrs |
|
|
| Epoxy
Primekote |
7hrs |
9hrs |
5hrs |
7hrs |
3hrs |
5hrs |
|
|
| Fiberglass
Bottomkote |
7hrs |
9hrs |
5hrs |
7hrs |
3hrs |
5hrs |
|
|
| Fiberglass
Bottomkote® ACT |
7hrs |
9hrs |
5hrs |
7hrs |
3hrs |
5hrs |
|
|
| Interlux
Antifouling |
7hrs |
9hrs |
5hrs |
7hrs |
3hrs |
5hrs |
|
|
| Interprotect
2000E |
5hrs |
2wks |
3hrs |
2wks |
2hrs |
2wks |
|
|
| Micron
66 |
7hrs |
9hrs |
5hrs |
7hrs |
3hrs |
5hrs |
|
|
| Micron
CSC |
7hrs |
9hrs |
5hrs |
7hrs |
3hrs |
5hrs |
|
|
| Micron
Extra with Biolux |
7hrs |
9hrs |
5hrs |
7hrs |
3hrs |
5hrs |
|
|
| Micron
Optima |
7hrs |
9hrs |
5hrs |
7hrs |
3hrs |
5hrs |
|
|
| Pre-Kote |
7hrs |
9hrs |
5hrs |
7hrs |
3hrs |
5hrs |
|
|
| Trilux
33 |
7hrs |
9hrs |
5hrs |
7hrs |
3hrs |
5hrs |
|
|
| Trilux
with Biolux |
7hrs |
9hrs |
5hrs |
7hrs |
3hrs |
5hrs |
|
|
| Ultra
with Biolux |
7hrs |
9hrs |
5hrs |
7hrs |
3hrs |
5hrs |
|
|
| ULTRA-KOTE |
7hrs |
9hrs |
5hrs |
7hrs |
3hrs |
5hrs |
|
|
|
|
Note:Overcoating
times will vary due to wide variations in temperature and humidity. The
best method is to check the paint film using the "Thumb Print"
test to determine when the Interprotect 2000E is ready to overcoat. If
the primer feels tacky and you can leave a thumb print in the paint film
without getting any paint on your thumb the Interprotect 2000E is ready
for overcoating. Test the paint film in the area where you started,
applying the primer 30 minutes after starting the application. Continue
testing every 15 minutes using the "Thumb Print" test until
reaching the Ready-to-Overcoat stage, then begin to apply Interlux
antifouling immediately. Do not apply if the relative humdity exceeds
85% or if the temperature is above 95°F (35°C). Check primed surfaces
using the "Thumb Print" test before overcoating with
antifouling. If you cannot leave a thumb print in the Interprotect 2000E
or it is "tack free" it is too late to overcoat and must be
removed. Follow application instructions on the antifouling label for
overcoating times of subsequent coats. |
|
|
| Preparation |
BARE
FIBERGLASS: Remove all surface contamination using Fiberglass
Surface Prep YMA601, flush with fresh water. Sand with 80 grade (grit)
paper. Remove sanding residue. Wipe with Fiberglass Solvent Wash 202.
Epiglass Epoxy Resin HT9000 or Interprotect 1000/1001®: Clean with
Fiberglass Surface Prep YMA601. Rinse with fresh water and allow to dry.
Sand with 80 grade (grit) paper. Remove sanding residue. Wipe with
Fiberglass Solvent Wash 202.
BARE METAL: Surface should be blasted to bright metal. Remove all
blast or sanding residue using a clean air line and sweeping with a
clean brush or broom. Vacuum clean for best results. Apply primer within
1 hour of metal preparation. If blasting is not possible (or if more
than 2 hours has passed since blasting) sand or grind with coarse emery
cloth and apply Viny-Lux® Primewash 353/354 prior to Interprotect 2000E
or Interprotect 3000/3001. |
|
|
| Method |
Apply
enough Interprotect 2000E to reach a final Dry Film Thickness of 10
mils. This usually takes 4-5 coats but the amount of paint is more
important than the number of coats. |
|
|
| Hints |
Mixing Ensure
the correct volume mix ratio is used. Mix thoroughly together and then
allow to sit 20 minutes for induction time. Mix only as much as you can
use in the stated pot life.
Cleaner Fiberglass Solvent Wash 202.
Airless Spray Pressure: 165 bar/2400 psi. Tip Size:
0.44-0.53 mm/17-21 thou.
Conventional Spray Pressure Pot: Pressure: 3.44-4.47
bar/50-65 psi (gun pressure); 10-15 psi (pot pressure). Tip Size:
1.5-1.8 mm/60-70 thou. Siphon Cup: Pressure: 3.44-4.47 bar/50-65 psi -
gun pressure. Tip Size: 1.8-2.2 mm/70-85 thou.
Brush Use a natural bristle brush.
Roller Use a 3/8" nap solvent resistant roller.
Other To figure out how much paint is necessary, calculate
as follows: Wetted Surface Area (WSA) = LOA x Beam x 0.85 Then divide
the WSA by 60 when brushing/rolling or 45 when spraying to determine the
number of gallons necessary to reach 10 mils. Prior to application of
Interprotect 2000E obtain and read the Interprotect System Manual. |
|
|
| Some
Important Points |
The
hull must be dry. Do not apply over one part paints. Product temperature
should be minimum 10°C/50°F and maximum 29°C/85°F. Ambient
temperature should be minimum 10°C/50°F and maximum 35°C/95°F.
Substrate temperature should be minimum 10°C/50°F and maximum 35°C/95°F. |
|
|
| Compatibility/Substrates |
Apply
to clean, dry, properly prepared surfaces only. Do not apply over one
part paints. When applying vinyl antifoulings such as VC Offshore and
Baltoplate® to Interprotect, apply an extra coat and allow epoxy to
cure overnight then sand with 80 grade (grit) paper to avoid wrinkling.
When overcoating with VC 17m or VC 17m Extra allow Interprotect 2000E to
dry for 24 - 36 hours, then sand with 180-220 grit sand paper. |
|
|
| Number
of Coats |
As
required to reach 10 mils DFT |
|
|
| Coverage |
(Theoretical)
- 240 (ft²/Gal) by brush, 180 (ft²/Gal) by spray |
|
|
| Recommended
DFT |
2.5
mils dry A minimum of 10 mils DFT is required for a complete blister
barrier.
|
| Recommended
WFT |
6.7
mils wet by brush |
|
|
| Application
Methods |
Brush,
Roller, Airless Spray, Conventional Spray - Pressure Pot or Siphon Cup |
|
| TRANSPORTATION,STORAGE
AND SAFETY INFORMATION |
| Storage |
TRANSPORTATION:
Interprotect 2000E should be kept in securely closed containers during
transport and storage.
STORAGE:
Exposure to air and extremes of temperature should be avoided. For the
full shelf life of Interprotect 2000E to be realised ensure that between
use the container is firmly closed and the temperature is between 5°C/40°F
and 35°C/95°F. Keep out of direct sunlight.
|
|
|
| Safety |
DISPOSAL:
Do not discard tins or pour paint into water courses, use the facilities
provided. It is best to allow paints to harden before disposal.
Remainders of Interprotect 2000E cannot be disposed of through the
municipal waste route or dumped without permit. Disposal of remainders
must be arranged for in consultation with the authorities.
GENERAL: Read the label safety section for Health and Safety
Information, also available from our Technical Help Line.
|
|
| IMPORTANT
NOTES |
The
performance of any marine paint or coating depends on many factors
outside the control of International Paint Inc., including surface
preparation, proper application, and environmental conditions.
Therefore, International Paint Inc. cannot guarantee this product's
suitability for your particular purpose or application. IMPLIED
WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND/OR MERCHANTABILITY
ARE EXCEEDED. International Paint Inc. SHALL NOT, UNDER ANY
CIRCUMSTANCES, BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. By
purchase of this product, the buyer agrees that the sole exclusive
remedy, if any, is limited to the refund of the purchase price or
replacement of the product at International Paint Inc. option. |
|